Aquaprufe APF-C-waterproof membrane (with sand)
PRODUCT DESCRIPTION
Aquaprufe APF-C pre-applied, fully bonded HDPE membrane consists of
multi-layer composite waterproofing material for superior waterproofing performance, including a layer of thick HDPE film, self-adhesive polymer layer and a unique particulate layer.
Aquaprufe APF-C pre-applied waterproofing membrane can be installed on uniform and regular concrete blinding, compacted sand-stone cushion for waterproofing of below ground surfaces and is also used for waterproofing of confined surfaces or blind side waterproofing.
Aquaprufe APF-C waterproofing membrane is designed to bond fully and permanently with poured concrete against it after placing and tying reinforcement.
WHERE TO USE
- Waterproofing below ground concrete structures
- .Protection of concrete foundations against aggressive ground contaminants.
- Prevents methane leakage in underground layers
Application: India International Convention&Expo Centre(IICC)
PRODUCT STRUCTURE
PRODUCT FEATURES
- Forms permanent bond to concrete poured against it, preventing water from seeping into the gap between waterproofing membrane and the structure
- Not affected by the displacement of the basal layer/ ground settlement beneath slabs
- Membrane is self-protecting. It can be trafficked immediately after application and does
not require the use of protective layer - Simple and quick to install, requiring no priming or fillets
- Unaffected by wet conditions
- Fully-adhered watertight laps and detailing
- Excellent bonding even under long-term water immersion
SPECIFICATION
Product name | Length | HDPE thickness | Membrane thickness |
---|---|---|---|
AQUAPRUFE APF-C PRE-APPLIED, FULLY BONDED HDPE WATERPROOF MEMBRANE
(WITH SAND) |
1m/2m
|
0.8mm
|
1.2mm
|
1.0mm
|
3.5mm
|
![]() |
![]() |
Sealed Tape
|
Sealant
|
DATABASE
Property
|
Typical Value
|
Test method
|
---|---|---|
Colour
|
White
|
|
Thickness
|
1.2mm
|
ASTM D 3767
|
Tensile Strength, One Direction, Film
|
≥25 Mpa
|
ASTM D 412 Modified
|
Tensile Strength, Other Direction, Film
|
≥21 Mpa
|
|
Elongation
|
≥400%
|
ASTM D 412 Modified
|
Low Temperature Flexibility -25ºC,
|
Pass
|
ASTM D 1970
|
Water Migration/Resistance to Hydrostatic Head
|
>70M
|
ASTM D 5385 Modified
|
Crack Cycling
|
Pass
|
ASTM D 836 / ASTM C 1305 Modified
|
Peel Adhesion to Concrete, No Treatment
|
≥880 N/m
|
ASTM D 903 Modified
|
Dimension Stability
|
< 2%
|
ASTM D 1204
|
Puncture Resistance
|
≥1000 N
|
ASTM E 154
|